Showing posts with label reading. Show all posts
Showing posts with label reading. Show all posts

Thursday, February 27, 2014

Nissan LEAF Battery Pouch Cells - Fire and Destruction Tests

In a LEAF Battery Module are 4 pouches, and these seem to be very tough !

- DON'T TRY THIS AT HOME -



- DON'T TRY THIS AT HOME -


"A used battery form Nissan Leaf 3.8V 33Ah, tested for how likely to catch fire when is destroyed or in flames. We had no success make it burn. Same battery after the burn test was charged/discharged twice at 1/3C - 10A - it has 30Ah capacity remaining. Before the test this cell was under salty water for 2 hours - you can see the contact are destroyed."














- DON'T TRY THIS AT HOME -

Sunday, November 10, 2013

Testing Wattson Transmitter to make it work for the US & Canada Split Phase Consumer Units

Last night and continuing today, I am in the process of testing Wattson transmitter capabilities to adapt to US and Canada Split Phase Consumer Units ...

Energeno is in still (?) waiting for UL Listing in the US, and other certifications I think, and their great Energy Monitor Wattson is coming to this new market soon

But in the meantime, I wanted to investigate and see for myself if I could make it works without waiting

Problems:
- With the Split Phase system in the US and Canada, consumer units have 2 hot wires carrying the 2 phases, split into 2 "legs", a left and right side column of breakers in the consumer unit; They have 2 sets of breakers bringing 120V AC fed by 2 different lines 
- Solar systems feed their Generated electricity to 240V directly 


What should be done to make it work:
- We have to measure the current passing through both "legs" and add these 2 to get total current, multiply it by 120V to get the Usage in Watts
- To measure 240V Generation at the output of the Solar Grid Tie Inverter, we need to measure one leg only


Findings: 
- If I plug a CT / Current sensor in socket 1 (normal usage set up), and another one in socket 2 of the transmitter, these 2 readings add up (perfect to measure both legs of a 120V consumer unit)
- Adding another CT / Current Sensor on the Production leg, and plugging it in the "Sun" socket, the Net Usage displayed on Wattson is 1 + 2 - Sun 

... to be continued ...









Before that, I opened the Transmitter to see how it is made, and measure some contacts




Please Share this Post if you Liked it !

Please Share this Post if you Liked it ! Thanks !